Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
2.
Rev. bras. med. esporte ; 27(4): 358-362, Aug. 2021. graf
Article in English | LILACS | ID: biblio-1288604

ABSTRACT

ABSTRACT Introduction: A new exercise electrocardiogram (ECG) detection system was investigated in this study to diagnose and analyze cardiopulmonary function and related diseases in a comprehensive and timely manner and improve the accuracy of diagnosis. Besides, its reliability and clinical applicability were judged. Objective: A new type of exercise ECG detection system was constructed by adding parameters such as respiratory mechanics, carbon dioxide, and oxygen concentration monitoring based on the traditional ECG detection system. Methods: The new system constructed in this study carried out the ECG signal detection, ECG acquisition module, blood pressure and respiratory mechanics detection and conducted a standard conformance test. Results: The heart rate accuracy detected by the exercise ECG system was greatly higher than that of the doctor's manual detection (P < 0.05). The accuracy of the new exercise ECG detection system increased obviously in contrast to that of the manual detection result (P < 0.05). The key technical index input noise and input impedance test results (24.5 μV and 12.4 MΩ) of the exercise ECG detection system conformed to the standard (< 30 μV and > 2.5 MΩ). The common-mode rejection and sampling rate test results (103.5 dB and 515 Hz) of key technical indicators in the exercise ECG detection system were all in line with the standards (≥89 dB and ≥500 Hz). Conclusion: The complete exercise ECG detection system was constructed through the ECG acquisition module, blood pressure detection, and respiratory mechanics detection module. In addition, this system could be applied to detect ECG monitoring indicators with high accuracy and reliability, which could also be extensively adopted in clinical diagnosis. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: Um novo sistema de detecção de eletrocardiograma de exercício (ECG) foi investigado neste estudo para diagnosticar e analisar a função cardiopulmonar e doenças relacionadas de maneira abrangente e oportuna e melhorar a precisão do diagnóstico. Além disso, sua confiabilidade e aplicabilidade clínica foram julgadas. Objetivo: Um novo tipo de sistema de detecção de ECG de esforço foi construído adicionando parâmetros como mecânica respiratória, dióxido de carbono e monitoramento da concentração de oxigênio com base no sistema de detecção de ECG tradicional. Métodos: O novo sistema construído neste estudo realizou a detecção do sinal de ECG, módulo de aquisição de ECG e detecção de pressão arterial e mecânica respiratória, e conduziu um teste de conformidade padrão. Resultados: A precisão da frequência cardíaca detectada pelo sistema de ECG de esforço foi muito maior do que a detecção manual do médico (P <0,05). A precisão do novo sistema de detecção de ECG de esforço aumentou obviamente em contraste com o resultado da detecção manual (P <0,05). O ruído de entrada do índice técnico principal e os resultados do teste de impedância de entrada (24,5 μV e 12,4 MΩ) do sistema de detecção de ECG de esforço estão em conformidade com o padrão (<30 μV e> 2,5 MΩ). A rejeição do modo comum e os resultados do teste de taxa de amostragem (103,5 dB e 515 Hz) dos indicadores técnicos principais no sistema de detecção de ECG de esforço estavam todos alinhados com os padrões (≥89 dB e ≥500 Hz). Conclusão: O sistema completo de detecção de ECG de esforço foi construído através da combinação de módulo de aquisição de ECG, detecção de pressão arterial e módulo de detecção de mecânica respiratória. Além disso, esse sistema poderia ser aplicado à detecção de indicadores de monitoramento de ECG com alta precisão e confiabilidade, o que poderia ser amplamente adotado no diagnóstico clínico. Nível de evidência II; Estudos terapêuticos- investigação dos resultados do tratamento.


RESUMEN Introducción: En este estudio se investigó un nuevo sistema de detección de electrocardiograma de esfuerzo (ECG) para diagnosticar y analizar la función cardiopulmonar y enfermedades relacionadas de manera integral y oportuna, y mejorar la precisión del diagnóstico. Además, se evaluó su confiabilidad y aplicabilidad clínica. Objetivo: Se construyó un nuevo tipo de sistema de detección de ECG de ejercicio agregando parámetros como la mecánica respiratoria, el dióxido de carbono y el monitoreo de la concentración de oxígeno sobre la base del sistema de detección de ECG tradicional. Métodos: El nuevo sistema construido en este estudio llevó a cabo la detección de la señal de ECG, el módulo de adquisición de ECG y la detección de la presión arterial y la mecánica respiratoria, y realizó una prueba de conformidad estándar. Resultados: la precisión de la frecuencia cardíaca detectada por el sistema de ECG de ejercicio fue mucho mayor que la de la detección manual del médico (P <0,05). La precisión del nuevo sistema de detección de ECG de esfuerzo aumentó obviamente en contraste con el resultado de la detección manual (P <0.05). Los resultados de la prueba de impedancia de entrada y ruido de entrada de índice técnico clave (24,5 μV y 12,4 MΩ) del sistema de detección de ECG de esfuerzo cumplieron con el estándar (<30 μV y> 2,5 MΩ). Los resultados de la prueba de frecuencia de muestreo y rechazo en modo común (103,5 dB y 515 Hz) de los indicadores técnicos clave en el sistema de detección de ECG de esfuerzo estaban en línea con los estándares (≥89 dB y ≥500 Hz). Conclusión: El sistema completo de detección de ECG de ejercicio se construyó mediante la combinación del módulo de adquisición de ECG, la detección de la presión arterial y el módulo de detección de la mecánica respiratoria. Además, este sistema podría aplicarse a la detección de indicadores de monitoreo de ECG con alta precisión y confiabilidad, que también podría adoptarse ampliamente en el diagnóstico clínico. Nivel de evidencia II; Estudios terapéuticos- investigación de los resultados del tratamiento.


Subject(s)
Electrocardiography/methods , Exercise Test , Heart Function Tests/instrumentation , Reproducibility of Results
3.
Rev. bras. med. esporte ; 27(8): 822-825, Aug. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1351840

ABSTRACT

ABSTRACT Introduction: The study and collection of athletes' heart function index parameters and the correct and reasonable evaluation of body functions can effectively adjust training plans and avoid athletes' bodily exhaustion. Objective: To study the diagnosis of myocardial injury by cardiovascular monitoring in athletes from two aspects: extraction of characteristic parameters of heart function and research of signal processing. Methods: The heart function intelligent evaluation algorithm was studied by using multi-source information fusion, and embedded technology; miniature sensors were used as well. Results: The incidence of severe ventricular arrhythmia was lower in both groups. The incidence of sinus arrhythmia and intermittent second degree I atrioventricular block in the high-intensity group was significantly higher than that in the control group. The number of atrial and ventricular premature beats was lower in the control group, but increased significantly in the high-intensity group. Conclusions: This study applied the theory of multi-source information fusion to carry out representative research on the intelligent monitoring and evaluation of the heart function of elite athletes, centering on the application requirements of the heart function monitoring of elite athletes. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: O estudo e a coleta de parâmetros indiciais da função cardíaca em atletas e a avaliação correta e razoável das funções corporais podem, efetivamente, levar ao ajuste de planos de treinamento e evitar a sobrecarga física de atletas. Objetivo: Estudar o diagnóstico da lesão miocárdica pelo monitoramento cardiovascular em atletas a partir de dois aspectos: a extração de parâmetros característicos da função cardíaca e a pesquisa do processamento de sinais. Métodos: O algoritmo de avaliação inteligente da função cardíaca foi estudado usando a fusão de informações de múltiplas fontes, além da tecnologia embarcada. Sensores em miniatura também foram usados. Resultados: A incidência de arritmia ventricular severa era menor nos dois grupos. A incidência de arritmia sinusal e o bloqueio atrioventricular de segundo grau do tipo I intermitente no grupo de alta intensidade foi significativamente mais alta do que no grupo de controle. O número de batidas prematuras atriais e ventriculares era menor no grupo de controle, mas aumentava consideravelmente no grupo de alta intensidade. Conclusões: Este estudo aplicou a teoria da fusão de informações de múltiplas fontes para conduzir uma pesquisa importante sobre o monitoramento e avaliação inteligentes da função cardíaca de atletas de elite, enfocando as exigências de aplicação do monitoramento da função cardíaca de atletas de elite. Nível de evidência II; Estudos terapêuticos - investigação de resultados de tratamento.


RESUMEN Introducción: El estudio y la recogida de parámetros indíciales de la función cardíaca en atletas y la evaluación correcta y razonable de las funciones corporales pueden efectivamente llevar al ajuste de planes de entrenamiento y evitar la sobrecarga física de atletas. Objetivo: Estudiar el diagnóstico de la lesión miocárdica a través del monitoreo cardiovascular en atletas a partir de dos aspectos: la extracción de parámetros característicos de la función cardíaca y la investigación del procesamiento de señales. Métodos: El algoritmo de evaluación inteligente de la función cerebral se estudió utilizando la fusión de informaciones de múltiples fuentes, además de la tecnología embebida. Sensores en miniatura también se utilizaron. Resultados: La incidencia de taquicardia ventricular severa era menor en los dos grupos. La incidencia de arritmia sinusal y bloqueo auriculoventricular de segundo grado del tipo I intermitente en el grupo de alta intensidad fue significativamente más alta que en el grupo de control. El número de contracciones prematuras auriculares y ventriculares era menor en el grupo de control, pero aumentaba considerablemente en el grupo de alta intensidad. Conclusiones: Este estudio aplicó la teoría de la fusión de informaciones de múltiples fuentes para conducir una investigación importante sobre el monitoreo y evaluación inteligentes de la función cardiaca de atletas de élite, centrando las exigencias de aplicación del monitoreo de la función cardíaca de atletas de élite. Nivel de evidencia II; Estudios terapéuticos - investigación de resultados de tratamiento.

4.
Rev. méd. Paraná ; 79(2): 36-39, 2021.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1368399

ABSTRACT

O lúpus eritematoso sistêmico (LES) é doença autoimune crônica. Uma das suas importantes complicações é o dano cardiovascular. O objetivo deste trabalho foi estudar a prevalência de disfunção cardíaca em uma população local com LES e verificar se o grau de disfunção está associado com o a atividade da doença medida pelo SLEDAI (Systemic Lupus erythematosus activity index). Foram selecionados 19 pacientes assintomáticos do ponto de vista cardiovascular com diagnóstico de LES e que preenchiam os critérios classificatórios. A atividade de doença foi medida pelo SLEDAI e a função cardíaca por ecocardiografia transtorácica. Em conclusão, não foi possível identificar disfunção cardíaca na amostra estudada. Pontuações mais altas no índice de atividade do lúpus demonstraram correlação com aumento de massa de ventrículo esquerdo e fração de ejeção.


Systemic lupus erythesis (SLE) is a chronic autoimmune disease. One of the important complications of this disease is the cardiovascular damage The objective of this work was to study the prevalence of cardiac dysfunction in a local population with SLE and to verify whether the degree of dysfunction is associated with the disease activity measured by SLEDAI (Systemic Lupus erythematosus activity index). Were selected 19 patients asymptomatic from cardiovascular point of view diagnosed with SLE and who met the classification criteria for SLE. Disease activity was measured by SLEDAI and cardiac function was evaluated by transthoracic echocardiography. In conclusion, cardiac dysfunction could not be identified in the sample studied. Higher scores in the lupus activity index showed a correlation with increased left ventricle mass and ejection fraction.

5.
J. pediatr. (Rio J.) ; 95(4): 475-481, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1040340

ABSTRACT

Abstract Objective: Mucopolysaccharidosis is a rare genetic disease characterized by the intralysosomal deposition of glycosaminoglycans. Cardiovascular impairment is a common feature. Cardiac signs and symptoms are underestimated due to the disease involvement in other organs. Enzyme replacement therapy can be used in mucopolysaccharidosis I, II, IV, and VI. Thus, the knowledge about the use of new echocardiography tools is relevant to improve the care of this population. This study aimed to describe left ventricular function assessment by conventional echocardiography and left ventricular global longitudinal strain analysis and compare the alterations in patients receiving enzyme replacement therapy and who had different ages at the start of therapy. Method: Outpatient-based descriptive study. The patients were submitted to conventional echocardiography and left ventricular global longitudinal strain measurement. Results: Sixteen patients were evaluated; median age of 14.2 years (SD = 5.2 years). Left ventricular hypertrophy was found in nine patients (56.2%). All patients had preserved left ventricular systolic function (Simpson and Teichholz). Nine (56.2%) patients showed alterations in left ventricular global longitudinal strain. The study showed a positive association between left ventricular hypertrophy and alteration in the left ventricular global longitudinal strain, and late start of enzyme replacement therapy and alteration in the left ventricular global longitudinal strain. Conclusion: Echocardiographic alterations in patients with mucopolysaccharidosis were frequently observed, especially alterations in the left ventricular geometry and subclinical dysfunction. Patients who had a late enzyme replacement therapy start showed an association with worse left ventricular global longitudinal strain values, reinforcing the need for early diagnosis and treatment. The use of new echocardiographic tools may improve the follow-up of these patients.


Resumo Objetivo: A mucopolissacaridose é uma doença genética rara, caracterizada por depósito intralisossômico de glicosaminoglicanos. O comprometimento cardiovascular é frequente. Sinais e sintomas cardíacos são subestimados pelo envolvimento da doença em outros órgãos. A terapia de reposição enzimática pode ser usada em mucopolissacaridose I, II, IV e VI. Assim, o conhecimento da aplicação de novas ferramentas de ecocardiografia é relevante para melhorar a assistência dessa população. Este estudo visou descrever a função do ventrículo esquerdo pelo ecocardiograma convencional e pela análise do strain global longitudinal do ventrículo esquerdo e comparar as alterações em pacientes que fazem uso da terapia de reposição enzimática e que tiveram idades distintas de início da terapia. Método: Estudo descritivo de base ambulatorial. Os pacientes foram submetidos à ecocardiografia convencional e medida do strain global longitudinal do ventrículo esquerdo. Resultados: Foram avaliados 16 pacientes; mediana de 14,2 anos (desvio: 5,2 anos). Hipertrofia do ventrículo esquerdo foi encontrada em nove pacientes (56,2%). Todos os pacientes tiveram função sistólica do ventrículo esquerdo preservada (Simpson e Teichholz). Nove (56,2%) pacientes apresentaram alteração no strain global longitudinal do ventrículo esquerdo. O estudo mostrou associação positiva entre hipertrofia do ventrículo esquerdo e alteração no strain global longitudinal do ventrículo esquerdo e início tardio da terapia de reposição enzimática e alteração no strain global longitudinal do ventrículo esquerdo. Conclusão: Alterações ecocardiográficas em pacientes com mucopolissacaridose foram frequentes, especialmente alterações na geometria e disfunção subclínica do ventrículo esquerdo. Pacientes que iniciaram tardiamente a terapia de reposição enzimática apresentaram associação com piores valores de strain global longitudinal do ventrículo esquerdo, o que reforça a necessidade do diagnóstico e tratamento precoces. O uso de novas ferramentas de ecocardiografia pode melhorar o acompanhamento desses pacientes.


Subject(s)
Humans , Male , Female , Child , Adolescent , Mucopolysaccharidoses/complications , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/diagnostic imaging , Myocardium/pathology , Echocardiography/methods , Cross-Sectional Studies , Mucopolysaccharidoses/drug therapy , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/drug therapy , Enzyme Replacement Therapy
6.
J. bras. pneumol ; 39(4): 440-446, June-August/2013. tab
Article in English | LILACS | ID: lil-686599

ABSTRACT

OBJECTIVE: To determine the probability of oxygen desaturation in healthy individuals undergoing the incremental shuttle walk test (ISWT). METHODS: We enrolled 83 healthy subjects: 55 males (including 1 smoker) and 28 females. We determined pre-ISWT FEV1, FEV6, HR and SpO2, as well as post-ISWT HR and SpO2. RESULTS: Mean values overall were as follows: age, 35.05 ± 12.53 years; body mass index, 24.30 ± 3.47 kg/m2; resting HR, 75.12 ± 12.48 bpm; resting SpO2, 97.96 ± 1.02%; FEV1, 3.75 ± 0.81 L; FEV6, 4.45 ± 0.87 L; FEV1/FEV6 ratio, 0.83 ± 0.08 (no restriction or obstruction); incremental shuttle walk distance, 958.30 ± 146.32 m; post-ISWT HR, 162.41 ± 18.24 bpm; and post-ISWT SpO2, 96.27 ± 2.21%. In 11 subjects, post-ISWT SpO2 was higher than was pre-ISWT SpO2. In 17 subjects, there was a 4% decrease in SpO2 after the ISWT. There were no statistically significant differences between the groups with and without post-ISWT oxygen desaturation in terms of age, gender, FEV1, FEV6, FEV1/FEV6, pre-ISWT SpO2, incremental shuttle walk distance, HR, or percentage of maximal HR. In the individuals with post-ISWT oxygen desaturation, the body mass index was higher (p = 0.01) and post-ISWT SpO2 was lower (p = 0.0001). CONCLUSIONS: Healthy individuals can present oxygen desaturation after the ISWT. Using the ISWT to predict subtle respiratory abnormalities can be misleading. In healthy subjects, oxygen desaturation is common after the ISWT, as it is during any intense physical activity. .


OBJETIVO: Determinar a probabilidade de dessaturação arterial em indivíduos saudáveis submetidos ao incremental shuttle walk test (ISWT). MÉTODOS: Foram estudados 83 indivíduos saudáveis, dos quais 55 eram homens (1 deles fumante) e 28 eram mulheres. Foram determinados VEF1 e VEF6 antes da realização do ISWT, assim como FC e SpO2 antes e depois do ISWT. RESULTADOS: As médias gerais foram as seguintes: idade, 35,05 ± 12,53 anos; índice de massa corporal, 24,30 ± 3,47 kg/m2; FC em repouso, 75,12 ± 12,48 bpm; SpO2 em repouso, 97,96 ± 1,02%; VEF1, 3,75 ± 0,81 L; VEF6, 4,45 ± 0,87 L; relação VEF1/VEF6, 0,83 ± 0,08 (sem restrição ou obstrução); distância percorrida no ISWT, 958,30 ± 146,32 m; FC pós-ISWT, 162,41 ± 18,24 bpm e SpO2 pós-ISWT, 96,27 ± 2,21% Em 11 indivíduos, houve um aumento da SpO2 após o ISWT, ao passo que em 17 houve uma queda de 4%. Não houve diferença estatística entre os grupos com e sem dessaturação após o ISWT no tocante às variáveis idade, gênero, VEF1, VEF6, VEF1/VEF6, SpO2 basal, distância percorrida no ISWT, FC e porcentagem da FC máxima. Nos indivíduos que apresentaram dessaturação, o índice de massa corporal foi maior (p = 0,01) e a SpO2 pós-ISWT foi menor (p = 0,0001). CONCLUSÕES: Indivíduos saudáveis podem apresentar dessaturação após o ISWT. O uso do ISWT para prever a presença de problemas respiratórios sutis pode ser enganador. Em indivíduos saudáveis, a dessaturação é um evento comum após o ISWT, assim ...


Subject(s)
Adult , Female , Humans , Male , Exercise Test/methods , Oxygen Consumption/physiology , Rest/physiology , Walking/physiology , Cross-Sectional Studies , Forced Expiratory Volume/physiology , Reference Values
7.
Acta cir. bras ; 25(6): 535-540, nov.-dez. 2010. graf, tab
Article in English | LILACS | ID: lil-567285

ABSTRACT

PURPOSE: To assess whether the tests - Forced Expiratory Volume at one second (FEV1), 6-minute walk test (6MWT) and stair-climbing test (SCT) showed proportional changes after the resection of functioning lung. METHODS: Candidates for pulmonary resection were included. Spirometry, 6MWT and SCT were performed preoperatively (pre) and at least 3 months after surgery (pos). SCT was performed on a staircase with a total ascent height of 12.16m. The time taken to climb the total height the fastest possible was defined as stair-climbing time (SCt). Number of functioning segments lost, was used to calculated predicted postoperative (ppo) tests values. Pre, ppo and pos values for each test were compared. Data were analyzed by repeated-measure ANOVA with significance level set at 5 percent. RESULTS: A total of 40 patients were enrolled. Pulmonary resection results ranged from gain of 2 functioning segments to loss of 9. Pre, ppo and pos values were the following: preFEV1 = 2.6±0.8L, ppo FEV1 =2.3±0.8L, and pos FEV1=2.3±0.8L, (pre FEV1 > ppo FEV1 = pos FEV1); pre6MWT = 604±63m, ppo6MWT= 529±103m, pos6MWT= 599±74m (pre6MWT = pos6MWT > ppo6MWT); preSCt = 32.9±7.6s, ppoSCt = 37.8±12.1s, posSCt = 33.7±8.5s (preSCt = posSCt < ppoSCt). CONCLUSION: In our group of patients, pulmonary resection led to loss of lung function measured by spirometry, but not to exercise capacity measured by stair-climbing and walk tests.


OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5 por cento. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Exercise Test , Exercise Tolerance/physiology , Forced Expiratory Volume/physiology , Lung/surgery , Walking/physiology , Analysis of Variance , Lung/physiopathology , Postoperative Period , Preoperative Care , Spirometry
8.
J. bras. pneumol ; 33(2): 128-133, mar.-abr. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-459281

ABSTRACT

OBJETIVO: Determinar a acurácia dos atributos do teste de escada (TE) de altura definida utilizando como padrão-ouro o consumo máximo de oxigênio (VO2 máx). MÉTODOS: O TE foi realizado com incentivo, em escada (6 lances; 72 degraus; 12,16 m de altura total), em 51 pacientes. O 'tempo' de subida foi cronometrado e o 'trabalho' e a 'potência' calculados. O VO2 máx foi obtido por ergoespirometria, utilizando-se o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p entre as variáveis do TE e o VO2 máx. Para o cálculo da acurácia, o ponto de corte do VO2 máx foi estabelecido em 25 mL/kg/min, estratificando os indivíduos em normais ou alterados. Os pontos de corte para os atributos do TE foram obtidos através da curva receiver operating characteristic. A estatística Kappa (k) foi utilizada para estudo da concordância. RESULTADOS: Obtiveram-se os seguintes valores para a variável 'tempo': ponto de corte = 40 s; x= 41 ± 15,5 s; r = -0,707; p < 0,005; especificidade = 89 por cento; sensibilidade = 83 por cento; acurácia = 86 por cento e k = 0,724. Para a variável 'potência', obteve-se ponto de corte = 200 w; x= 222,3 ± 95,2 w; r = 0,515; p < 0,005; especificidade = 67 por cento; sensibilidade = 75 por cento; acurácia = 71 por cento e k = 0,414. A correlação de 'trabalho' com o VO2 máx não foi significativa, sendo esse atributo descartado. CONCLUSÃO: Dos atributos testados do TE, tendo como padrão-ouro o VO2 máx, a variável 'tempo' foi a que apresentou a melhor acurácia.


OBJECTIVE: To determine the accuracy of the variables related to the fixed-height stair climbing test (SCT) using maximal oxygen uptake (VO2 max) as the gold standard. METHODS: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing 'time' was measured, and the variables 'work' and 'power' also being calculated. The VO2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and VO2 max. To determine accuracy, the VO2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. RESULTS: The following values were obtained for the variable 'time': cut-off point = 40 s; x= 41 ± 15.5 s; r = "0.707; p < 0.005; specificity = 89 percent; sensibility = 83 percent; accuracy = 86 percent; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; x= 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67 percent; sensibility = 75 percent; accuracy = 71 percent; and k = 0.414. Since the correlation between 'work' and VO2 max was not significant, that variable was discarded. CONCLUSION: Of the SCT variables tested, using VO2 max as the gold standard, the variable 'time' was the most accurate.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Exercise Test/methods , Oxygen Consumption/physiology , Epidemiologic Methods , Ergometry , Exercise Test/standards , Motivation , Motor Activity/physiology , Spirometry , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL